Accessories
Vocia PLD-2
Passive end of speaker line supervision device (4-pack).
Key features
- Passive end of line monitoring
- Compatible with the Vocia VA-4300CV and VA-8150CV
- No added cabling required
- Easy to install
- Compatible with most installed loudspeakers
- Maximum speaker length 4,300ft (1,300m) of non-branching speaker line (varies with load and wire gauge)
- 5-year warranty
- Compliant with the US Trade Agreement Act (TAA)
The Vocia PLD-1 and PLD-2 are passive end of line devices for use with Vocia amplifiers (PLD-1: Vocia VA-8600; PLD-2: VA-4300CV and VA-8150CV) on constant voltage systems. Each Vocia amplifier uses a pilot tone to ensure speaker line integrity between itself and the PLD. The device can be surface mounted.
The Vocia PLD-1 and PLD-2 comply with the United States Trade Agreement Act (TAA), allowing it to be included in GSA Schedule contractors’ sales bids for the U.S. federal government.
| General | |
|---|---|
| Length | 8.9 inches (225 mm) (Cable Length) |
| Height | 1.7 inches (44 mm) |
| Width | 2.4 inches (60 mm) |
| Depth | 0.5 inches (12 mm) |
| Specification Notes | Line Monitoring: 70V/100V constant voltage Pilot Tone: PLD-1: 18.4kHz (VA-8600) PLD-2: 20.2kHz (VA-4300CV, VA-8150CV) Maximum Channel Power Rating: 70V: 150W 100V: 300W Loudspeaker Distance: Up to 4,300ft (1,300m), varies with load and speaker wire gauge. |
| Certified Solutions | |
| TAA Compliant | TAA Compliant |
| Certified Solutions | TAA Compliant |
| Compliance | |
| Compliance | UL and C-UL listed (USA and Canada) CE Marked (Europe) RoHS Directive (Europe) Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces |
Related products

Commercial Audio MA3060-19
Accessories19-inch bracket kit for the Commercial Audio MA30 & MA60 mixing amplifiers.

Commercial Audio MA35-19
Accessories19-inch bracket for the Commercial Audio MA35 and MA65 mixing amplifiers.

Plenum Box 12 x 12
Accessories12-inch x 12-inch, fire-resistant enclosure used to install a variety of Biamp devices in plenum spaces. It is UL2043 compliant and meets Chicago Building Code Chapter 14E-3 requirements.

Vocia ELD-1
AccessoriesEnd of line device, surface-mountable, networked speaker line supervision device.


Vocia PARM-1
Amplifier ModulesVocia Page Active Relay Module Card, factory installed.


Vocia PLD-1